Description:
|
The VR8200A 2132 standing pilot, features continuous pilot dual automatic valve combination. This unit comes with 1/2" x 1/2" inlet\outlet, has standard opening with pressure regulator setting is 3.5" wc, and has 20-200cfm capacity. The VR8200 Controls replace Honeywell V800A and VR800A models, White Rodgers 36C03/01 series, Robert Shaw 7000BER (700 - 400) and 7200ER (720 - 400) series, ITT B57 and B59 series, Essex SX242N.
|
Honeywell VR8200A 2132 Standing Pilot Gas Valve Features:
|
- Type: Single Stage
- Ignition Type: Standing Pilot
- Type of Gas: Natural
- Inlet/Outlet Size: 1/2 in. x 1/2 in.
- Body Pattern: Straight-through
- Opening Characteristics: Standard
- Capacity: 130,000 BTU/hr; 20,000 BTU/hr minimum
- Pressure Ratings: 1/2 psi
- Pressure Ratings: 3.5 kPa
- Pressure Regulator Setting (psi): 3.5 in. wc
- Pressure Regulator Setting (kPa): 0.87 kPa
- Pilot Gas Outlet Compression fitting for 1/4 in. OD tubing
- Pressure Tapping 1/8 in. NPT with plug
- Electrical Connections: Combination screw and 1/4 in. male quick connects.
- Electrical Ratings: 24 Vac/60 Hz 0.5 A
- Temperature Range: 0 F to 175 F/-18 C to +79 C
- Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically
- Dimensions: 5 3/16" H x 4 1/8" W x 3 1/4" D
- Dimensions: 132 mm H x 104 mm W x 83 mm D
- Includes: 1/2" x 3/8" reducer bushing; 39369014 bag assembly-3/4" straight flange with O ring, screws and wrench and 393691 Natural to LP gas conversion kit.
|